An Electrical Installation Condition Report (EICR) is a formal assessment of the fixed electrical installation within a property.

Call us on 01483 000000 (placeholder - not in service)

EICR

An Electrical Installation Condition Report (EICR) is a formal assessment of the fixed electrical installation within a property. It covers the consumer unit, all wiring, sockets, switches, and earthing and bonding arrangements.

The purpose of an EICR is to establish whether the installation is in a satisfactory condition and identify anything that poses a danger, requires urgent attention, or does not meet current standards. The assessment is carried out by a qualified electrician who inspects and tests each circuit in the property.

Visual checks are made on the consumer unit, connections, and accessible wiring. Each circuit is then tested for continuity, insulation integrity, polarity, and earth fault loop impedance.

The results are recorded and compared against the requirements of BS 7671, the UK wiring regulations. At the end of the assessment, a report is produced.

Observations are recorded using a classification system: items classified C1 represent a danger requiring immediate action; C2 items require urgent attention; C3 items are recommendations for improvement; and FI codes indicate where further investigation is needed. A property receives an overall assessment of satisfactory or unsatisfactory.

EICRs are required in certain circumstances. Landlords in England are legally required to hold a valid EICR for each rented property and to provide a copy to tenants.

EICRs are also often requested when purchasing a property, following a change of occupancy, or where there is reason to believe the installation may have deteriorated. For owner-occupied properties, an EICR is recommended at regular intervals — typically every ten years — though older installations or those that have been extended or altered without certification may warrant more frequent assessment.

Signs your installation may be due for an assessment

⚠️

No certificate available

If you have moved into a property and there is no electrical installation certificate or recent EICR, the condition of the installation is unknown. This is particularly relevant for older properties where wiring may not have been formally checked for many years.

⚠️

Flickering lights or tripping breakers

Regularly flickering lights, circuits that trip under normal load, or an RCD that trips without obvious cause can indicate wiring faults, overloaded circuits, or deteriorated insulation. These are exactly the symptoms an EICR is designed to investigate and document.

⚠️

Visible signs of old wiring

Rubber-sheathed cables, round-pin sockets, or a fusewire board are indicators of an older installation. These features suggest the wiring was installed under earlier standards and has not been updated, making an EICR a sensible first step before any remedial or extension work.

⚠️

Change of tenancy or upcoming property transaction

Landlords are legally required to hold a valid EICR. For properties being sold, a recent EICR can reassure prospective buyers about the state of the installation. Carrying out an assessment ahead of a transaction avoids uncertainty or delays during the conveyancing process.

How an EICR is carried out

1

Visual inspection

The electrician begins with a thorough visual check of the consumer unit, accessible wiring, sockets, switches, and any specialist equipment. They look for signs of deterioration, damage, incorrect installations, or missing protective measures such as adequate earthing and bonding.

2

Circuit testing

Each circuit is isolated in turn and tested for continuity of protective conductors, insulation resistance, polarity, and earth fault loop impedance. The electrician records the results and compares them against the values specified in BS 7671 for the type and size of cable used in each circuit.

3

Reporting and classification

An EICR records the inspector's assessment, observations and next inspection date. Ask a qualified inspector to explain any C1, C2, C3 or further-investigation (FI) entries, the required action and timescale. Landlords must complete required remedial or investigative work and retain written confirmation.

4

Follow-up recommendations

Where C2 or C3 items are noted, the electrician can advise on appropriate remedial steps. For C1 items, action should be taken without delay. Where FI codes are recorded, further investigation — which may involve exposing wiring or testing additional circuits — is required before a final assessment can be made.

FAQs About EICR

What does an EICR check?
An EICR covers the entire fixed electrical installation: the consumer unit, all circuits including ring finals, radials, and lighting circuits, sockets, switches, earthing and bonding conductors, and any special locations such as bathrooms. The electrician carries out both a visual inspection and a series of electrical tests on each circuit.
How often should an EICR be carried out?
In England, rented homes require electrical installation inspection and testing at intervals of no more than five years, or sooner if the report specifies. A new tenancy alone does not require a new inspection where the existing report remains valid and required work has been completed. The landlord must give the new tenant the report before occupation. Safety concerns may justify earlier inspection.
What do the condition codes on an EICR report mean?
Read the inspector's recorded overall assessment and every observation. C1 means danger present and C2 means potentially dangerous; these require remedial action. C3 recommends improvement. Further investigation (FI) must not be ignored: ask the qualified inspector what investigation is required and follow the report's timescale. For rented homes in England, required remedial or investigative work must be completed within 28 days, or sooner where the report requires, with written completion evidence.
What happens if the EICR finds problems?
If the report contains C1 or C2 observations, these need to be addressed. C1 items indicate a danger that should be rectified without delay; C2 items require prompt attention. Once remedial work is completed, a re-inspection or follow-up check may be needed to confirm the issues have been resolved. Your electrician can advise on the appropriate course of action based on the specific observations recorded.

More Electrical Inspections & Testing services

EICR CostPAT TestingLandlord Electrical Certificate

Other services in Guildford

🏠 Fuse Board / Consumer Unit Replacement ⚡ Rewiring 🔌 Lighting & Sockets 🏠 EV Charger Installation ⚡ Emergency Electrician

Related guides

Understanding electrical inspections in GuildfordUnderstanding RCDs and circuit breakers in Guildford

Areas

Contact